CMP EARTH TAGS

CMP slip-on Earth Tags, installed between the Cable Gland and equipment, provide an earth bond connection as specified in BS6121:Part 5:1993 and comply with category B rating specified in IEC 62444. CMP Earth Tags have been independently short circuit tested to verify their suitability under specified service conditions. A copy of the test report is available upon request and is an important factor when selecting earth tags from any manufacturer, as without this the safety of installations may be compromised.



Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

Download [0.96 MB]

CABLE GLAND SS316L CMP TE1FU M32

CMP CABLE GLAND SS316L TE1FU M32
TE1FU | Ex e, Ex d, Ex nR, Ex ta | Explosive Atmosphere Cable Gland
For all types of Armoured Cables
Globally Approved, Explosive Atmosphere Cable Gland
Stainless steel compact design
Fully sequential, three step installation procedure
Reduces installation times, cost & risk
Direct & remote installation
Unique compensating displacement seal system(CDS)
Metal-to-metal installation regardless of cable bedding diameter
Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
Integral protected deluge seal
Controlled outer load retention seal
Unique OSTG prevents overtightening
-60C to +130C
Globally marked, IECEx, ATEX & cCSAus
EMC tested
 

Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

 
Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

CABLE GLAND SS316L CMP TE1FU M25 with EARTH TAGS

CMP CABLE GLAND SS316L M20, COMPLETE EARTH TAGS
Globally Approved, Explosive Atmosphere Cable Gland
Stainless steel compact design
Fully sequential, three step installation procedure
Reduces installation times, cost & risk
Direct & remote installation
Unique compensating displacement seal system(CDS)
Metal-to-metal installation regardless of cable bedding diameter
Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
Integral protected deluge seal
Controlled outer load retention seal
Unique OSTG prevents overtightening
-60C to +130C
Globally marked, IECEx, ATEX & cCSAus
EMC tested
*ABOUT EARTH TAGS*
Material: STAINLESS STEEL
CMP slip-on Earth Tags, installed between the Cable Gland and equipment, provide an earth bond connection as specified in BS6121:Part 5:1993 and comply with category B rating specified in IEC 62444. CMP Earth Tags have been independently short circuit tested to verify their suitability under specified service conditions. A copy of the test report is available upon request and is an important factor when selecting earth tags from any manufacturer, as without this the safety of installations may be compromised.
 

Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

 
Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

 

CABLE GLAND BODY CMP TE1FU M20s

CABLE GLAND BODY CMP TE1FU M20s
Material: 316L Stainless Steel
Part BODY for Cable Gland CMP m20s

Key Features of CMP Cable Glands

Above is a typical CMP double seal Cable Gland showing the parts in an exploded view

(1) Unique Independent Inner Sealing
The CMP inner sealing principal is quite different from other cable gland types and because the activation of the inner sealing ring is separated from the armour clamping components this means that the possibility of inadvertent over-tightening is eliminated. Unlike traditional compression seals that have no means of direct control on their application, the CMP inner sealing technique is achieved using a displacement seal that is independently controlled by the user during installation.
The Compensating Displacement Seal System (1) has helped CMP to take its original displacement sealing ring concept to another level. The unique Compensator has allowed the cable gland components to be fully tightened metal-to-metal and relieve the potential excess forces that could be transferred to the cable bedding, eliminating potential cable damage and coldflow.
(2) (3) Secure Armour Termination
CMP Products’ armour clamping method involves a unique termination solution that ensures a permanent crimping of the cable armour, creating a low impedance connection that does not suffer from self-loosening. The patented AnyWayTM clamping ring aids an easy ‘Right First Time’ installation. Secure armour clamping like this also contributes to enhanced levels of EMC performance as well as reliable earth continuity.
(4) Outer Seal
The unique CMP Products Outer Seal Tightening Guide (OSTG) and Load Retention Sealing Ring (LRS) ensure an IP/NEMA rated seal is formed around the cable to the correct degree. As similar solution is also provided for the sealing rings in our Cable Glands for unarmoured cables.
(5) Proven Internally Enclosed Deluge Seal
CMP Products integrated ‘O’ ring deluge seal (tested to DTS 01:91) prevents corrosion of the cable armour by ensuring that moisture cannot track around the Cable Gland threads and into the armour termination body. As an internally enclosed deluge seal the ‘O’ ring is protected from mechanical damage and harmful UV rays.

 

 

TE1FU | Ex e, Ex d, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Armoured Cables

Globally Approved, Explosive Atmosphere Cable Gland
• Stainless steel compact design
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of cable bedding diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested

 
TECHNICAL:

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications* Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate SIRA13ATEX1073X
SIRA13ATEX4079X
Code of Protection II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc, I M2, Ex d I Mb, Ex e I Mb
Compliance Standards EN60079-0,1,7,15,31
IECEx Certificate IECEx SIR 13.0028X
IECEx SIM 14.0007X
Code of Protection Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 – 90) 1310517
CSAus Code of Protection Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 4X, Oil Res II
Class I, Zone 1, AEx e II, AEx nR II
cCSA Code of Protection Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 3, 4 and 4X,
Ex d IIC, Ex e IIC, Ex nR II
Compliance Standards CAN/CSA-C22.2 No 0, 18, 25, 30, 94, 174, CAN/CSA-E60079-0, 1, 7,
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0, 1, 7
EAC Certificate C-GB.AA87.B.00487
NEPSI Certificate GYJ18.1253X
CCOE / PESO (India) Certificate P333688
INMETRO Approval TÜV 11.0374X
Marine Approvals LRS: 01/00172, DNV: TAE00000Y, ABS: 14-LD234401A-4-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g SWB)
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath
Sealing Ring : Load Retention Seal (LRS)
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

Note : *Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request